Axis II Biometer & Pachymeter -Quantel Medical Ultrasonic Biometry & Pachymetry Axis II. Advanced ultrasound contact biometry system which provides precise measurements of axial length in patients with dense cataracts (even when biometrics using the IOLMaster cannot be carried out) very quickly and efficiently, to calculate the strength of intraocular lenses. Pavilion talking electronic chess user manual.
- Quantel Medical today announced the CE mark approval of LacryStim TM IPL system. Based on intense pulsed light technology, LacryStim TM is used for the treatment of dry eye diseases such as Meibomian gland dysfunction. Dry eye disease is a multifactorial disease of the tears and ocular surface that can result in ocular discomfort and visual impairment.
- Founded in 1970, Lumibird is one of the world's leading specialists in laser technology for scientific (laboratories and universities), industrial (material processing, process analytics, marking) and medical (ophthalmology) markets. Lumibird lasers (pulsed Nd:YAG lasers, fiber lasers, laser diodes and tunable laser systems) are used in applications ranging from.
- If you are searched for the book User manual quantel medical in pdf form, then you have come on to correct website. We present the full edition of this book in PDF, txt, DjVu, doc, ePub forms.
- Apr 17, 2015 Used QUANTEL MEDICAL Axis II A-Scan SE de Vende - DOTmed Lista #1774163: Pre-owned Axis II A-Scan ultrasound biometer: Only one in stock, and READY TO SHIP! Ships for FREE anywhere in the U.S.! Includes: Dust cover Probe and solid tip probe Foot pedal User manual Original brochure The A scan echogram is made up of 1,5000 points.
Ophthalmoscopes, refraction units, slitlamps, keratometer, retinoscopes, tonometer, perimeter, pachymeter and chart projectors.
First some documents of the maintenance of ophthalmic equipment in general:
Basic Care and maintenance of Ophthalmic Equipment
ORBIS instruction1.2 MB Download
Mantenimiento y cuidado basico de Equipos oftalmologicos
Instruction de ORBIS390 KB Download
Surgical Microscopes
ORBIS preventive maintenance instructions53 KB Download
Alcon Infiniti Ophthalmic Surgical Instrument
Service manual4.7 MB Download
Alcon Phaco Machine Series 20000 Legacy
Service manual26.4 MB Download
Bon CP-33 Chart Projector
Instruction manual430 KB Download
Bon CP-50 Chart Projector
Instruction manual270 KB Download
Bon DigiPro3 Software
Installation manual4.0 MB Download
Bon E-20 SE Refraction Unit
Instruction manual640 KB Download
Bon E-30 Refraction Unit
Instruction manual770 KB Download
Bon E-40 Refraction Unit
Instruction manual770 KB Download
Bon EM-2 Specular Microscope
Instruction manual2.8 KB Download
Bon E-50 Refraction Unit
Instruction manual550 KB Download
Bon SL-72, SL-75 Slitlamp
Instruction manual970 KB Download
Bon SL-85 Slitlamp
Instruction manual550 KB Download
Bon SL-E Slitlamp
Instruction manual520 KB Download
Bon SL-Zoom Slitlamp
Instruction manual550 KB Download
Bon T-900, A-900,Z-800 Tonometer
Quantel Medical Compact Ii
Instruction manual390 KB Download
Erbe Ophthalmobipolar
Service manual4.8 MB Download
Haag-Streit Octopus 300 Perimeter
Service manual3.5 MB Download
Heidelberg Edge Perimeter
Configuration manual3.4 MB Download
Heidelberg Retina Angiograph 2
Installation manual3.2 MB Download
Heidelberg Retina Angiograph 2
System configuration manual4.1 MB Download
Heidelberg Retina Camera
Installation instructions1.7 MB Download
Heidelberg Retina Tomograph 3
Configuration manual1.3 MB Download
Heidelberg Retina Tomograph 3
Installation manual1.8 MB Download
Heidelberg SL-OCT Slitlamp
Installation manual2.0 MB Download
Heidelberg SL-OCT Slitlamp
Quick guide50 KB Download
Heidelberg SL-OCT Slitlamp Video Kit
Installation manual2.4 MB Download
Heidelberg Spectralis HRA+OCT
Installation guide2.3 MB Download
Heidelberg Spectralis OCT
Installation instruction710 KB Download
Humphrey Field Analyzer Series 700
Field service guide.pdf11.1 MB Download
Humphrey Field Analyzer II-i Series
Service manual7.8 MB Download
Humphrey Field Analyzer II-i Series
Field service guide.pdf10.5 MB Download
Icare Tonometer
Installation instruction1.5 MB Download
Inami - General Maintenance for Tonometer
Maintenance manual870 KB Download
Inami Slitlamp L-0185 L-0187
Maintenance manual370 KB Download
Keeler Portable Slit Lamp
Service manual1.5 MB Download
Keeler Pulsair 2000-3000 Tonometer
Service manual660 KB Download
Keeler Vantage + Ophthalmoscope
Service manual1.9 MB Download
Lambda Physik OPTex Excimer Laser
Maintenance manual2.9 MB Download
LKS Utas
Installation guide2.3 MB Download
LKS Utas
Service manual700 KB Download
Luneau L60 Refractometer
Function description1.4 MB Download
Meditec MQL-10 Eye Laser
Service manual2.8 MB Download
Meditec MQL-10 Eye Laser
Service manual3.3 MB Download
Nidek AR-600, ARK-700
Calibration manual15.2 MB Download prohibited by Nidek. Support is not desired.
Nidek AR-600, ARK-700
Service manual3.2 MB Download prohibited by Nidek. Support is not desired.
Nidek ARK-710 Autorefractometer
Service manual4.5 MB Download prohibited by Nidek. Support is not desired.
Nidek ARK-730 Autorefractometer
Service manual3.0 MB Download prohibited by Nidek. Support is not desired.
Nidek CV-24000
Service manual9.0 MB Download prohibited by Nidek. Support is not desired.
Nidek DC-3300 Photocoagulator
Service manual980 KB Download prohibited by Nidek. Support is not desired.
Nidek GYC-1000 Laser Coagulator
Service manual5.1 MB Download prohibited by Nidek. Support is not desired.
Nidek GYC-1000 Photocoagulator
Technical training7.3 MB Download prohibited by Nidek. Support is not desired.
Nidek RT-5100 Refractometer
Service manual7.7 MB Download prohibited by Nidek. Support is not desired.
Nidek SL-1600 Slit Lamp
Service manual1.0 MB Download prohibited by Nidek. Support is not desired.
Nidek SL-1800 Slit Lamp
Maintenance manual15.4 MB Download prohibited by Nidek. Support is not desired.
Nidek US-800 Echoscan
Service manual975 KB Download prohibited by Nidek. Support is not desired.
Nidek YC-1600 YAK Laser
Service manual4.3 MB Download prohibited by Nidek. Support is not desired.
Nidek YC-1800 YAG Laser
Service manual7.2 MB Download prohibited by Nidek. Support is not desired.
Heine Het Set
Exploded view520 KB Download
Quantel Aviso
Service manual5.1 MB Download prohibited by Quantel. Support is not desired.
Quantel Axis II
Service manual11.9 MB Download prohibited by Quantel. Support is not desired.
Quantel Optimis II
Service manual890 KB Download prohibited by Quantel. Support is not desired.
Quantel Pocket II
Service manual690 KB Download prohibited by Quantel. Support is not desired.
Quantel Solutis
Service manual2.5 MB Download prohibited by Quantel. Support is not desired.
Quantel Supra
Service manual18.9 MB Download prohibited by Quantel. Support is not desired.
Scan Optics Cable
Wiring diagram20 KB Download
Scan Optics SO-161
Service manual210 KB Download
Scan Optics SO-111, 151, 161, 5000, 5100, 5600, 5800
Service manual1.4 MB Download
Scan Optics SO-5800
Assembly manual250 KB Download
Schwind Refractive Surgery
Information2.1 MB Download
Schwind Esiris Excimer Laser
Service manual2.9 MB Download
Schwind OPTex
Axis Companion User Manual
Technical training1.4 MB Download
Shin-Nippon Accuref-K
Service manual1.4 MB Download
Shin-Nippon BR-7
Service manual320 KB Download
Shin-Nippon CP-20, 30, 40
Service manual1.2 MB Download
Shin-Nippon SLM-4000, 5000
Service manual
1.5 MB Download
Shin-Nippon XL-1
Service manual85 KB Download
Thomey SP-100 Pachymeter
Service manual85 KB Download
Topcon SL-D7 Slitlamp
Service manual670 KB Download
Unicos URK-700 Keratometer
Service manual3.3 MB Download
Wagner+Guder Motiva
Circuit diagram125 KB Download
Zeiss Indirect Ophthalmoscope
Technical manual280 KB Download prohibited by Zeiss. Support is not desired.
Zeiss IOL Master Slitlamp
Axis Ii Clusters
Service manual3.1 MB Download prohibited by Zeiss. Support is not desired.
Zeiss Stratus OCT 3000 Coherence Tomographer
Service manual5.9 MB Download prohibited by Zeiss. Support is not desired.
Zeiss Visulas 531 Slitlamp
Service manual52.4 MB Download prohibited by Zeiss. Support is not desired.
Zeiss Visulas 532 Laser
Service manual12.6 MB Download prohibited by Zeiss. Support is not desired.
Zeiss Visulas YAG III Laser
Service manual5.5 MB Download prohibited by Zeiss. Support is not desired.
Pre-owned Axis II A-Scan ultrasound biometer:
Only one in stock, and READY TO SHIP! Ships for FREE anywhere in the U.S.!
Includes:
Dust cover
Probe and solid tip probe
Foot pedal
User manual
Original brochure
The A scan echogram is made up of 1,5000 points. The Axis II gives you the possiblity to zoom and reposition the markers in the presence of pathology which may have affected the readings. It also caters to the difficult-to-measure eye: dense cataract, long eyes, pseudo-phakic eyes assuming the specific speeds for PMMA, and both acrylic and silicone lenses. Sound speeds may even be varied by the user to account for new materials.
Acquistion can be made using the contact method, probe hand-held, or fixed on the tonometer holder. But also using the immersion method, to insure no corneal compression and guarantee measurement along the optical axis.
The Axis II can store all the data obtained for up to 20 patients in the internal memory. This allows the echograms to be reviewed and the I.O.L. calculations to be done later, at your convenience. You may also input the information on up to 40 lenses to have at your fingertips.
Formulae : SRK T, SRK II, Holladay, Binkhorst II, Hoffer Q, Haigis
9 values bracketed for desired ametropia for each lens
2 different IOLs calculated simultaneously
Measurements : Anterior chamber, lens , vitreous and total length
Automatic calculation of standard deviation, average and statistical analysis of results
Only one in stock, and READY TO SHIP! Ships for FREE anywhere in the U.S.!
Includes:
Dust cover
Probe and solid tip probe
Foot pedal
User manual
Original brochure
The A scan echogram is made up of 1,5000 points. The Axis II gives you the possiblity to zoom and reposition the markers in the presence of pathology which may have affected the readings. It also caters to the difficult-to-measure eye: dense cataract, long eyes, pseudo-phakic eyes assuming the specific speeds for PMMA, and both acrylic and silicone lenses. Sound speeds may even be varied by the user to account for new materials.
Acquistion can be made using the contact method, probe hand-held, or fixed on the tonometer holder. But also using the immersion method, to insure no corneal compression and guarantee measurement along the optical axis.
The Axis II can store all the data obtained for up to 20 patients in the internal memory. This allows the echograms to be reviewed and the I.O.L. calculations to be done later, at your convenience. You may also input the information on up to 40 lenses to have at your fingertips.
Formulae : SRK T, SRK II, Holladay, Binkhorst II, Hoffer Q, Haigis
9 values bracketed for desired ametropia for each lens
2 different IOLs calculated simultaneously
Measurements : Anterior chamber, lens , vitreous and total length
Automatic calculation of standard deviation, average and statistical analysis of results